Answer:
It is likely that the System Option "Disable AC Fail Detection" was enabled, thus the loss of power was ignored. To enable AC fail detection:
...
View Answer
Answer:
There is already an instance of Windows Quickloader running on your PC, likely minimized on your Taskbar.
Note: After selecting OK in the popup, a new "Unable to Continue, Database Error!" message appears.
View Answer
Answer:
In UL Listed Burglary installations, the control panel keypad must annunciate when the StarLink communicator goes into trouble, not solely when there is Telco line trouble or a 'fail to communicate' trouble.
...
View Answer
Answer:
The FWC-FSLC-EZM2 Dual Input Monitor Module is an addressable SLC two-zone conventional input module providing two independent contact monitoring circuits while only utilizing one address on the SLC loop. Designed to be used with pull stations,...
View Answer
Answer:
The "Pass Time" is the duration the lock stays unlocked after a valid User Code entry.
...
View Answer
Answer:
Yes, the privacy button located on the DL/PDL4100 lock can be replaced by ordering part number 9DL41INHSG26D. This replacement consists of the complete battery cover and includes the privacy button.
...
View Answer
Answer:
All Alarm Lock Trilogy T3 series locking devices have these options for programming:
...
View Answer
Answer:
To update the DL-Windows Event Log and view the latest information:
...
View Answer
Answer:
Yes, the IBR-ZREMOTE can be optionally programmed using a browser in place of the NL-MODCONFIG software, as follows:
...
View Answer
Answer:
After the first download to a GEMC control panel, PCD-Windows Quickloader will lock out fire programming abilities to ensure the integrity of the AHJ approved fire program configuration and protect against inadvertent downloads. To allow for...
View Answer
Answer:
In PCD-Windows Quickloader software, select System Assignment > System Reporting and Outputs tab. Add a check to the Test Timer option for Report on Alarm Telco 1:
...
View Answer
Answer:
Battery degradation is the gradual loss of a battery's ability to store and deliver energy over time. It is a natural process that happens to all batteries, and it is caused by a variety of factors, including:
...
View Answer
Answer:
The polling rate between the NAPCO Prima Super Panel and all other system devices is 25 seconds.
...
View Answer
Answer:
In the NAPCO Prima Super Panel, the number of events stored depends upon the total file size of all events compared with the allocated storage space. Events with images take up more storage space thus decreasing the total number stored.
...
View Answer
Answer:
The Prima PCAM Indoor/Outdoor HD Camera and PBELL Wi-Fi HD doorbell camera are programmed to sense only human movement. These cameras are intentionally programmed to ignore animals, vehicles, or other types of motion thus preventing the storage...
View Answer
Answer:
From the Prima main screen, tap MENU.
Enter your Master (Dealer) Code:
Tap Arming.
Tap the function you wish to change, Staying or Leaving.
Disable the voice annunciations as desired.
View Answer
Answer:
The Abort Delay feature delays the reporting of a zone-trip alarm to allow for cancellation before the alarm report is sent to the central station. For example, if a zone programmed for Abort Delay trips while the system is armed, the central...
View Answer
Answer:
If you see "Bad Phone Number" in the Response column of your NOC Signal Log, ensure that the telephone number programmed in your control panel is a real receiver telephone number.
...
View Answer
Answer:
Yes, you can! If your DL-Windows database is lost or corrupted and you install a new instance of DL-Windows, the following data can be retrieved directly from previously programmed Trilogy T3 door locks:
...
View Answer
Answer:
Only Administrative users or Basic users who have been given Emergency command authorization credentials may initiate these functions.
...
View Answer
Answer:
Yes, you can use every type of Gateway in a single system concurrently with other Gateways, with some limitations.
...
View Answer
Answer:
Yes. When Function 69, "Enable [Star] as Enter Key" is enabled, entering Program Mode requires that you hold the [AL] key after entering the Master Code (instead of a single press-and-release).
View Answer
Answer:
Place the control panel into configuration mode by placing jumper JP5 from the top two pins ("NORMAL") to the lower two pins ("CONFIG").
...
View Answer
Answer:
Although each StarLink communicator housed in a metal enclosure is factory equipped with a tamper switch, the switch is non-operational by design; closing the enclosure door does not close the tamper switch. If your installation requires a...
View Answer
Answer:
Setting up your first Prima account is simple. Credentials that will allow you to access the Prima dealer portal website (www.NapcoPrima.Pro) will be emailed to you after activating your account on the NAPCO ComNet website...
View Answer
Answer:
If your newly installed wired doorbell camera does not detect motion, first wait 15 minutes for the automatic firmware update process to complete. Like many electronic devices, it is best to ensure the latest firmware is installed. At the...
View Answer
Answer:
The NAPCO Prima PCAM wireless camera and PWBELL wireless doorbell camera do not perform status check-ins. Although both cameras each contain a 'heartbeat' that is used strictly for supervision to the Prima Super Panel, but the heartbeat does...
View Answer
Answer:
Perform the deletion in the NAPCO ComNet website (www.NapcoComNet.com).
...
View Answer
Answer:
The keypad message appears because the selection Remote Access Only was enabled in the PCD-Windows Quickloader Keypad Assignment screen. When this selection is enabled, the selected keypad is changed to only accept Access codes and not arm /...
View Answer
Answer:
In PCD-Windows Quickloader software, select Panel History > Status History.
...
View Answer
Answer:
The network path failure code is due to the Service Plan being changed to a 'Sole Path' plan (in www.NapcoComNet.com) but the selection IP with Cell Radio Backup in the NAPCO NOC (www.NapcoNOC.com) was not changed (i.e., remained selected).
...
View Answer
Answer:
NAPCO Prima installations do not require central station monitoring; however, the Prima system must still be registered at the ComNet website (www.NapcoComNet.com) and a service plan must be purchased in order to provide system notifications and...
View Answer
Answer:
The PSMKCO Supervised Digital Wireless Smoke / Carbon Monoxide Detector uses only one zone in the Prima Super Panel. The detector sends a different signal to the Super Panel depending on whether it detects a fire or carbon monoxide, therefore...
View Answer
Answer:
After a processing period of up to 15 minutes after registering a new Prima account on the ComNet website (www.NapcoComNet.com) it will become visible in the Prima dealer portal website (www.NapcoPrima.Pro).
View Answer
Answer:
Wi-Fi connectivity issues may result in decreased battery life due to longer buffering times. The minimum suggested Wi-Fi signal strengths for both the Prima wireless camera and wireless doorbell camera are:
...
View Answer
Answer:
The following are the minimum control panel firmware versions that can be used with the NetLink NL-RCM Remote Control Module:
...
View Answer
Answer:
One of the most common mistakes when adding zones to a control panel is forgetting to add the zone to an Area. The Quickloader screen below shows zones that are not assigned to an Area (arrows):
...
View Answer
Answer:
This message often appears shortly after first registering a StarLink communicator followed by the immediate attempt to activate and program the communicator in the NOC. The solution is to simply power the StarLink communicator and wait for the...
View Answer
Answer:
The word "Terminate" indicates the Subscriber Identity Module (SIM) for that StarLink communicator --the data storage module containing its identity-- has been suspended, has been permanently deactivated and will require replacement.
View Answer
40 Results Per Page | Showing
1-40 of 1970 Results
| 1 |
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
15
|
16
|
17
|
18
|
19
|
20
|
21
|
22
|
23
|
24
|
25
|
26
|
27
|
28
|
29
|
30
|
31
|
32
|
33
|
34
|
35
|
36
|
37
|
38
|
39
|
40
|
41
|
42
|
43
|
44
|
45
|
46
|
47
|
48
|
49
|
50